Configuration of the camera
PIKE Technical Manual V4.0.0
314
Advanced register: frame counter
Different to Marlin SIS: Register 610 is only to be used to reset the frame
counter. The frame counter feature is controlled by the following advanced
feature register:
Having this feature enabled, the current frame counter value (images read
out of the sensor, equivalent to # FrameValid) will be inserted as a 32-bit
integer value into any captured image.
Setting the Reset flag to 1 resets the frame counter to 0 — the Reset flag
is self-cleared.
Additionally there is a register for direct read out of the frame counter value.
Bit0123456789101112131415
Cycle offset 12 bit Cycle count ...
Bit16171819202122232425262728293031
... Cycle count 13 bit Second count 7 bit
Table 164: Cycle timer layout
Register Name Field Bit Description
0xF1000610 FRMCNT_STAMP Presence_Inq [0] Indicates presence of this
feature (read only)
Reset [1] Reset frame counter
--- [2..31] Reserved
0xF1000614 FRMCNT [0..31] Frame counter
Table 165: Advanced register: frame counter
Note
L
The 4 bytes of the frame counter value will be inserted as
the 5th to 8th byte of a line.
Comentários a estes Manuais