Allied Vision Technologies Pike Manual de Instruções Página 295

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 332
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 294
Configuration of the camera
PIKE Technical Manual V4.0.0
295
To reload a shading image from non-volatile memory:
1. Set MemoryChannel to the desired memory channel and
MemChannelLoad to true (1).
2. Read MemChannelError to check for errors.
To clear already stored shading image data in non-volatile memory (shading
image data won't be loaded on camera resets):
1. Set MemoryChannel to the desired memory channel and
MemChannelClear to true (1).
2. Read MemChannelError to check for errors.
Memory channel error codes
ID Error description
0x00 No error
0x01 Memory detection error
0x02 Memory size error
0x03 Memory erase error
0x04 Memory write error
0x05 Memory header write error
0x0F Memory channel out of range
Table 145: Memory channel error description