Configuration of the camera
STINGRAY Technical Manual V2.2.0
260
Maximum resolution
This register indicates the highest resolution for the sensor and is read-only.
Time base
Corresponding to IIDC, exposure time is set via a 12-bit value in the corre-
sponding register (SHUTTER_INQ [51Ch] and SHUTTER [81Ch]).
This means that you can enter a value in the range of 1 to 4095.
Stingray cameras use a time base which is multiplied by the shutter register
value. This multiplier is configured as the time base via the TIMEBASE regis-
ter.
The time base IDs 0-9 are in bit [28] to [31]. See Table 121: Time base ID on
page 261. Refer to the following table for code.
Default time base is 20 µs: This means that the integration time can be
changed in 20 µs increments with the shutter control.
Note
L
This register normally outputs the MAX_IMAGE_SIZE_INQ
Format_7 Mode_0 value.
This is the value given in the specifications tables under
Picture size (max.) in Chapter Specifications on page 38ff.
Register Name Field Bit Description
0xF1000200 MAX_RESOLUTION MaxHeight [0..15] Sensor height
(read only)
MaxWidth [16..31] Sensor width
(read only)
Table 119: Advanced register: Maximum resolution inquiry
Register Name Field Bit Description
0xF1000208 TIMEBASE Presence_Inq [0] Indicates presence of this
feature (read only)
--- [1..7] Reserved
ExpOffset [8..19] Exposure offset in µs
--- [20..27] Reserved
Timebase_ID [28..31] See Table 121: Time base ID
on page 261.
Table 120: Advanced register: Time base