Allied Vision Technologies AVT Stingray Manual de Instruções Página 143

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 309
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 142
Description of the data path
STINGRAY Technical Manual V2.2.0
142
The following screenshot shows the sequence of commands needed to work
with deferred mode.
For a description of the commands see the following table:
Figure 86: Example: Controlling deferred mode (SmartView - Direct Access; Stingray F-145C)
# rw Address Value Description
11 rd F1000260 82006900h Check how many images are left in FIFO
10 wr F1000260 86006901h Read out the second image of FIFO
9 rd F1000260 82006901h Check how many images are left in FIFO
8 wr F1000260 86006901h Read out the first image of FIFO
7 rd F1000260 82006902h Check that two images are in FIFO
6 wr F0F0061C 82000000h Do second one-shot
5 wr F0F0061C 82000000h Do first one-shot
4 wr F1000260 82000A00h Switch deferred mode on
3 rd F1000260 80000A00h Check pres. of deferred mode and FIFO size (0Ah 10 frames)
2 wr F0F00614 00000000h Stop continuous mode of camera
1 rd F0F00614 00000000h Starting SmartView
Table 50: Example: Controlling deferred mode (SmartView - Direct Access; Stingray F-145C)
Vista de página 142
1 2 ... 138 139 140 141 142 143 144 145 146 147 148 ... 308 309

Comentários a estes Manuais

Sem comentários